Repair POL Laboratory B606
Agency: | DEPT OF DEFENSE |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159530302184646 |
Posted Date: | Nov 16, 2022 |
Due Date: | Dec 16, 2022 |
Solicitation No: | QJKL-22-0011-934CONF |
Source: | https://sam.gov/opp/580535c6e0... |
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Sources Sought (Updated)
- All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
- Updated Published Date: Nov 16, 2022 08:10 am CST
- Original Published Date: Nov 16, 2022 08:04 am CST
- Updated Response Date: Dec 16, 2022 03:00 pm CST
- Original Response Date: Dec 16, 2022 03:00 pm CST
- Inactive Policy: 15 days after response date
- Updated Inactive Date:
- Original Inactive Date:
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS
-
NAICS Code:
- 236220 - Commercial and Institutional Building Construction
-
Place of Performance:
Minneapolis , MN 55450USA
Contractor shall provide all supervision, labor, materials and equipment necessary to fully meet all requirements of the Statement of Work, Construction Specifications, Construction Drawings and all other Contract Documents related to and/or titled: Repair POL Laboratory B606. The performed tasks shall be based on the project description, other data furnished in the Statement of Work (SOW), and information covered during the Pre-Construction (Pre-CON) meeting. The scope of work for the project is to replace existing cabinets, flooring, install additional HVAC ducting, and repair roof top unit Hot Gas Reheat (HGRH) dehumidification system in B606. A facility of adequate size and configuration is necessary to maintain a Type C++ laboratory rating. Principal features of the work are, but not limited to; demolish existing casework and VCT flooring, place new monolithic flooring to include cove base, install new metal casework, install new 50 CFM explosion proof exhaust fan above existing ceiling with ducting intake vent no more than 6 inches above lab floor. Service roof top unit HGRH to ensure operating temperature maintain 73° F +/- 5° F (23 +/- 2 ° C), 55° F (13° C) maximum dew point, and humidified if relative humidity drops below 30%. Apply (1) coat primer (2) coats of semi-gloss paint to match existing room color throughout entire room. This general outline of the principal features does not in any way limit the responsibility of the Contractor to perform all work required by the plans and statement of work.
- CP 612 713 1430 (NOT FOR SHIPPING) 760 MILITARY HWY BLDG 729
- MINNEAPOLIS , MN 55450-2100
- USA
- Karen Gillen
- karen.gillen@us.af.mil
- Phone Number 6127131427
- Chin Dahlquist
- chin.dahlquist.1@us.af.mil
- Phone Number 6127131426
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.