Minnesota Bids > Bid Detail

Project parameters: • Nature of this project is largely dictated by the fact that these VAV’s are located in a working area and these offices will not be able to be vacated while the work is being completed. • Removal of 31 VAV or duct heaters while protecting the ceiling grid and duct to allow for restoration, some areas may require slight modification, the contractor will offer an approved proposal for this and complete the work. • Provide 31 VAV’s, 480 volt electric reheats, expected sizes. 18 – 2 kW units, 9 - 4 kW units and 4 – 6 kW units. Lay out attached. • Controllers, space sensors and all digital actuators will be provided by UHL companies. Spec sheet is attached. • Each location will need to be scheduled, so a plan can be in place the keep disruptions to a minimum. • Contractor will be required to remove all waste and maintain a clean work area as it will remain occupied for the duration of the project. • All work will be expected to be completed in a neat and work

Agency: State Government of Minnesota
Level of Government: State & Local
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
  • S - Utilities and Training Services
  • Y - Construction of Structures and Facilities
  • Z - Maintenance, Repair or Alteration of Real Property
Opps ID: NBD15628950404232127
Posted Date: May 13, 2019
Due Date: May 31, 2019
Solicitation No: 19-6002
Source: http://www.mmd.admin.state.mn....

REFERENCE NUMBER: C4355
PROJECT NUMBER: 19-6002
CONTRACTING AGENCY: Minnesota Zooalogical Gardens

RESPONSE TO THIS SOLICITATION IS DUE NO LATER THAN 05/31/19 AT 12:01 PM CENTRAL TIME.

PRE-BID MEETING DATE: 05/22/19 at 09:00 AM CENTRAL TIME Not Mandatory
MEETING DETAILS: Meet at East Gate, will proceed to location. Limited access, please contact Dan Haugen for informational packet. dan.haugen@state.mn.us
CONTACT PERSON: Dan Haugen
CONTACT PHONE: 612.393.7611
LOCATION OF WORK: Minnesota Zoo Admin. building
DESCRIPTION: Project parameters: • Nature of this project is largely dictated by the fact that these VAV’s are located in a working area and these offices will not be able to be vacated while the work is being completed. • Removal of 31 VAV or duct heaters while protecting the ceiling grid and duct to allow for restoration, some areas may require slight modification, the contractor will offer an approved proposal for this and complete the work. • Provide 31 VAV’s, 480 volt electric reheats, expected sizes. 18 – 2 kW units, 9 - 4 kW units and 4 – 6 kW units. Lay out attached. • Controllers, space sensors and all digital actuators will be provided by UHL companies. Spec sheet is attached. • Each location will need to be scheduled, so a plan can be in place the keep disruptions to a minimum. • Contractor will be required to remove all waste and maintain a clean work area as it will remain occupied for the duration of the project. • All work will be expected to be completed in a neat and workman like manor. All safety protocol will be expected to be followed at all times. • This work will be complete on a 2 – 10 pm shift this will allow better access for the contractor as well as less disruptions for the zoo.
FURTHER DESCRIPTION: After the selection process has been completed, a schedule will be created with the winning bidder which can hopefully lend to a profitable and productive project. Minnesota zoo staff will complete electrical, and UHL company will complete the controls and integration into our Andover system.

Date This Solicitation Was Posted: 5/13/2019 6:46:25 AM